Rouleau
3-ply highly permeable roof lining and sarking membrane which is suitable for laying on boarding, MDF and fibreboard roof lining panels and insulating mats and boards.
Material | |
Protective and covering fleece | Polypropylene microfibre |
Membrane | monolithic TEEE |
Attribute | Norm | Value |
Colour | anthracite | |
Surface weight | EN 1849-2 | 115 ±5 g/m² |
Thickness | EN 1849-2 | 0.40 mm ±0.05 mm |
Water vapour resistance factor µ | EN ISO 12572 | 125 |
sd-value | EN ISO 12572 | 0.05 ±0.02 m |
g-value | 0.25 ±0.1 MN·s/g | |
Water vapor permeance | ASTM E 96 | 65.6 US perms |
Fire behaviour | EN 13501-1 | E |
Exposure time | 3 months | |
Water column | EN 20811 | 10 000 mm |
Water resistance un-/aged* | EN 1928 | W1 / W1 |
Tensile strength MD/CD | EN 12311-2 | 220 ±15 N/5 cm / 185 ±15 N/5 cm |
Tensile strength MD/CD aged* | EN 12311-2 | 185 ±15 N/5 cm / 160 ±15 N/5 cm |
Elongation MD/CD | EN 12311-1 | 60 ±20 % / 70 ±20 % |
Elongation MD/CD aged* | EN 12311-1 | 40 ±20 % / 50 ±20 % |
Nail tear resistance MD/CD | EN 12310-1 | 130 ±30 N / 135 ±30 N |
*) Artificial ageing by long term | EN 1297 / EN 1296 | passed |
Flexibility at low temperature | EN 1109 | -40 °C/-40 °F |
Temperature resistance | -40 °C/-40 °F to +100 °C/212 °F | |
Coefficient of thermal conductivity | 0.17 W/m·K | |
Sarking membrane/roof lining membrane | ZVDH-Produktdatenblatt | USB-A / UDB-B |
Temporary roof covering; suitable as ... | ZVDH | yes |
CE labelling | EN 13859-1 | available |
SOLITEX MENTO membranes should be laid with the printed side facing the installer. They can be laid taut either at right angles to or along the eaves without sagging as a roof lining membrane or sarking membrane. Horizontal installation (along the eaves) is preferable with regard to water tightness during the construction phase. When using as a sarking membrane the spacing between the rafters is restricted to 100 cm.
The membrane must not be secured in areas where water collectively drains off (e.g. in grooves).
In the case of uninsulated, undeveloped attic floors, ridge ventilation should be provided. For this purpose, the SOLITEX membrane should finish 5 cm before the ridge. In addition, the undeveloped attic floor should be provided with permanent ventilation devices.
To protect the structure during the building phase, as specified by ZVDH ('Zentralverband des Deutschen Dachdeckerhandwerks' - National Association of the German Roofing Trade), SOLITEX MENTO 1000 roof lining and sarking membrane can be used as a temporary roof cover for up to 3 months. In this case the roof pitch must be at least 14°. The system components TESCON NAIDECK nail sealing tape, ORCON F joint adhesive and TESCON VANA for sticking overlaps or joints must be used. The connect version has two self-adhesive zones for secure exterior sealing. The standards and guidelines of the German roofing trade association must be observed during installation and sealing.
According to the technical regulations of the roofing trade association, they are suitable as a sarking membrane for covering a tiled roof with simple overlapping as an additional protective measure against rain. When using as a roof lining membrane with simple overlapping on a timber shell, the SOLITEX MENTO membranes are also suitable at elevated requirements as an additional protective measure against rain.